A
B
A)
supplied seal
B)
supplied brackets
If you install the hob under a
hood, please see the installation
instructions of the hood for the
minimum distance between the
appliances.
CAUTION!
Install the appliance only on a
worktop with flat surface.
8.7 Possibilities for insertion
Kitchen unit with door
The panel installed below the hob must
be easy to remove and let an easy access
in case a technical assistance intervention
is necessary.
min 20 mm
(max 150 mm)
30 mm
60 mm
B
A
A)
Removable panel
B)
Space for connections
Kitchen unit with oven
The electrical connection of the hob and
the oven must be installed separately for
safety reasons and to let easy remove
oven from the unit.
9. TECHNICAL INFORMATION
Hob dimensions
Width: 894 mm
Length: 510 mm
Hob recess dimensions
Width: 830 mm
Length: 480 mm
Heat input
Triple Crown burner: 4.0 kW
Rapid burner: 3.0 kW
Semi-rapid burner: 2.0 kW
Auxiliary burner: 1.0 kW
TOTAL POWER: G20 (2H) 20 mbar = 13.0 kW
G30 (3+) 28-30 mbar = 931 g/h
G31 (3+) 37 mbar = 914 g/h
Electric supply: 230 V ~ 50 Hz